Rock Ridge River Canyon Natural Marble Ledger Panel
| Supplier | Floor & Decor |
|---|---|
| Panel size | 8 × 24 in. |
| SKU | 101022556 |
| Material | Natural marble |
View River Canyon at Floor & Decor ↗
Natural-marble ledger panels give the fireplace face a textured finish.
5309 Meadow Chase · Fireplace
The existing Heatilator remains in place. A new stone face moves forward, with fitted veneer returning to the recessed opening.
The ceiling rises away from the fireplace wall into the room; the finished stone top is scribed to the sloped ceiling plane. The fireplace face and mantel remain level. Dimensions and mantel options below remain subject to final construction verification.
.png)
CURRENT DESIGN · VIS-02 · TF-MC-5309
The listed Heatilator and chimney stay in their installed position. A new architectural plane comes approximately 5–6 in forward; the firebox therefore reads as recessed. VIS-02 is the current design presentation. The diagrams below explain details and remain subject to field and manufacturer verification.
01 · Stone and mantel
River Canyon natural marble forms the fireplace face. A custom floating metal mantel offers a choice of sizes and finishes.
Rock Ridge River Canyon Natural Marble Ledger Panel
| Supplier | Floor & Decor |
|---|---|
| Panel size | 8 × 24 in. |
| SKU | 101022556 |
| Material | Natural marble |
View River Canyon at Floor & Decor ↗
Natural-marble ledger panels give the fireplace face a textured finish.
Custom floating metal mantel
Stoll Industries makes metal shelves and mantels in custom sizes and multiple finishes.
Explore Stoll’s custom metal mantels ↗
Room finishes
Review the stone, flooring and trim together. Use physical samples to choose the room’s finish palette before ordering.
Mantel: Provide the product photo, link, quote or fabricator name. Confirm material, finish, overall width, depth, visible thickness and mounting details.
Textured veneer covers the broad face. Smooth materials finish the firebox returns and outside corners.
02 · Room and ceiling
The stone face sits between windows beneath a ceiling that rises outward into the room. The gas firebox stays at its current wall plane.
03 · Fireplace and hearth
The mantel extends across the stone face. Compare the fireplace with and without a projecting hearth.
Earlier Concept / Superseded: The image below predates VIS-02. Refer to the VIS-02 board above for the current room and ceiling geometry.



TF-MC-5309 · Design control
The rendering shows the recessed fireplace direction. Every item below is open; the image does not record owner approval, trade verification or a fabrication release.
Choose the direction. Confirm the recessed opening with fitted stone returns, metal mantel and hearth treatment. The image shows no raised hearth; required floor protection remains to be checked.
Identify the appliance. Photograph the Heatilator rating plate to settle HD42B versus HD42BI; identify the installed gas insert and reconcile its listing with Heatilator documents 12955 and 12063.
Resolve the wall section. Measure the original wall, factory surround, proposed face and both inner and outer returns. The 2 × 4 + ½-inch board + approximately 1-inch stone build-up suggests about 5–6 inches. Draw a dimensioned section that preserves required air spaces.
Set the mantel and hearth. Check the 72-inch metal mantel, 4-inch side overhangs and 12-inch total depth against the applicable clearance chart; determine safe elevation, thickness, heat rating, structural anchors and required hearth extension.
Mock up the finish. Use the larger, mostly white stones from the bottom of the field sample. Confirm actual lot blend, varied piece sizing, fitted corner and opening returns, substrate and adhesive with the installer.
Preserve access. Keep doors/glass removal, louvers, convection gaps, lower service path and the gas key/shutoff reachable. Have a qualified trade review any valve or piping change.
Issue the shop detail. Record opening and floor datums, ceiling intersection, finished depth, fire clearances, blocking, brackets, joints, hearth and utilities. Obtain the responsible owner, GC and qualified-trade signoffs before material orders or fabrication.
Earlier Concept / Superseded: the two earlier room views compare floor treatments only. Their finer strip-stone texture and mantel finish are superseded by the current material and recessed-return concept above.
CONFIRMED · Field baseline
The lowest existing stone row has been removed. Confirm finished framing, clearances and the new wall plane in the field.
05 · Gas fireplace
The existing Heatilator wood-burning fireplace remains in place with its gas insert. The gas-key drive, escutcheon and shutoff/service path must stay reachable at the new face; verify key length and compatible trim with the qualified gas trade. Its approximately 42-inch field width indicates the HD42 family; the data plate must confirm the suffix and the insert listing. Documents 12955 (April 14, 1988) and 12063 (June 6, 1988) guide the current review.
DECISION NEEDED · Final metal mantel
VIS-02 studies a 64-inch face projecting approximately 5–6 inches from the original wall and a 72-inch-wide metal mantel reaching 12 inches from that wall. It overruns the face by 4 inches on each side and suggests roughly 6–7 inches of exposed shelf beyond the finished stone. The owner board depicts an illustrative 8-inch shelf; reconcile that dimension with the measured finished face before fabrication.
TBD: exact finished face depth, mantel thickness, elevation, finish, fabricator and structural attachment. Set mantel elevation from the exact appliance clearance requirements and measured geometry. The approximately 12 in overall hearth remains a working concept; thickness and construction method remain open.
MANUFACTURER VERIFY · Front options
No manufacturer-listed extension kit has been verified for the presumed Heatilator HD42B / HD42BI. A fabricated firebox extension is not an approved design. After photographing the data plate, check listed trim, surround, door and front assemblies that might reduce the recessed appearance without moving the fireplace or chimney.
Working identification: Heatilator HD42 family; exact suffix FIELD VERIFY. Manufacturer documents 12955 (4-14-88) and 12063 (6-6-88) inform the review but do not replace exact model verification.
DECISION NEEDED · Owner review
The gas shutoff and service path remain permanently accessible. Any valve or piping change needs separate trade review.
06 · Fireplace installation
Working assembly and manufacturer references; verify against the data plate and the listed gas insert before construction release.
Likely Heatilator HD42B / HD42BI; exact suffix pending rating plate. Review the 1988 installation instructions (12955), alternate chimney supplement (12063), and the installed gas insert’s listing together.
Maintain the manual’s minimum 2-inch air space around chimney sections to the enclosure, including top framing, for the full chimney height. Keep vapor barrier and loose insulation away. The new framing and finishes must not bridge required air spaces.
VIS-02 uses a working approximately 5–6-inch finished face based on 2 × 4 framing (3½-inch depth), ½-inch cement board and approximately 1-inch veneer. Verify actual build-up and listed clearances in the dimensioned section. Use fitted noncombustible returns; verify allowable overlap at the factory face.
Preserve glass/door removal, louvers, convection openings, lower service access and reachable gas key/shutoff. Appliance and chimney stay fixed; any gas piping change requires qualified trade review.
The manual’s typical framing figure labels a 42⅛-inch header, 55-inch reference height and 10-inch maximum projection example. These do not set the mantel elevation here. Check the applicable mantel chart, combustible zones, noncombustible facing and hearth extension for the verified unit and insert.
Photograph the data plate and issue a dimensioned section showing opening datum, finished depth, clearances, blocking, structural mantel brackets, joints, hearth, returns and access before fabrication.
07 · Hearth, returns and mantel
Choose the hearth, return material and mantel with your general contractor before pricing, ordering or fabrication.
Choose a flush base or projecting hearth after checking the fireplace manual’s requirements.
Working design: individually fitted River Canyon veneer wraps the shallow recessed opening. Confirm its transition to the factory surround.
Provide your preferred mantel’s product details. Confirm material, finish, dimensions, mounting and elevation against the fireplace manual.